Message
MEMORY ERROR
DUMP ERROR
RECEIVE ERROR
XMEM ERROR
LOAD ERRORS
Possible Reason
CODE BYTE IS NOT CORRECT IN
EEPROM MEMORY.
MIDI INFORMATION IS BEING
RECEIVED AT THE MIDI IN AT THE
SAME INFORMATION IS BEING
DUMPED.
MIDI SYSTEM EXCLUSIVE
INFORMATION WAS NOT
RECEIVED CORRECTLY.
EEPROM MEMORY IS NOT BEING
STORED TO CORRECTLY.
MIDI SYSTEM EXCLUSIVE
INFORMATION WAS NOT
RECEIVED CORRECTLY OR
STORED CORRECTLY.
Corrective Action
MAKE SURE EEPROM IS TIGHT IN
SOCKET.
MAKE SURE WITHIN CORRECT
OPERATING TEMPERATURE.
DISCONNECT MIDI CORD AT MIDI
IN OF TRANSMlTTING
MULTIVALVE.
BULK LOAD WAS TRANSMITTED
TOO FAST.
CHECK SUM BYTE WAS NOT
CORRECT.
DATA STRINGS NOT CORRECT
LENGTH.
DATA STRINGS OUT OF ORDER.
MAKE SURE EEPROM IS TIGHT IN
THE SOCKET.
MAKE SURE WITHIN THE CORRECT
OPERATING TEMPERATURE.
CHECK RECEIVE ERROR AND
XMEM ERROR.
ERROR MESSAGES